null

Nordson EFD Ultimus I: High Precision Fluid Dispenser System

Contact Us for Quote
No reviews yet Write a Review
SKU:
EFD 7017041
  • Great Value

  • BEST PRICE

  • Safe Payments

  • Amazing Selection

Nordson EFD Ultimus I:  High Precision Fluid Dispenser

High-precision benchtop fluid dispensing control for advanced applications of glue, oil, grease, epoxy, silicone, sealant, cyanoacrylate, solder paste, and other assembly fluids dispensed with syringe barrels. Featuring a digital display of all fluid dispenser settings and time adjustment as fine as 0.0001 seconds, Ultimus™ I-II dispensers bring exceptional control to medical device, electronics, and other critical dispensing processes. Ultimus I features 0-100 psi (0-7 bar) constant-bleed air pressure regulation and provides greater control when dispensing any type of fluid. Ultimus II features 0-15 psi (0-1 bar) constant-bleed air pressure regulation and provides greater control when dispensing low-viscosity or thin fluids.

Features:

  • All-digital, multi-function display
  • 16 memory settings
  • 4-decimal time setting
  • Operator lockout of time setting
  • Multilingual display options
  • Universal power supply

 

Benefits:

  • Simultaneous digital display of all dispensing parameters for better process control
  • Save up to 16 dispensing programs to easily transition from one type of application to the next
  • Time setting adjustments ≥ 0.0001 for a higher level of precision
  • Operator lockout to maintain a more consistent process

 

Specifications:

  • Cabinet size: 14.3W x 18.1H x 17.3D cm (5.63W x 7.12H x 6.82D")
  • Weight: 2.3 kg (5.0 lb)
  • Power adapter:

                    -AC input: 100–240 VAC (+/-10%), ~50/60Hz, 0.6A

                    -DC output: 24 VDC @ 1.04A

  • End-of-cycle feedback circuits: 5–24 VDC; 100mA maximum
  • Initiate circuits: Foot pedal, finger switch, or 5–24 VDC signal
  • Cycle rate: Exceeds 600 cycles per minute
  • Time:

                     -Range:Programmable from 0.0001–999.9999 seconds

                     -Accuracy: Within ±0.05% of the selected time setting

                     -Repeatability: Less than 16 μsec at any time setting

  • Pressure readout accuracy: ±2.0 psi, 0–7.0 bar (0–100 psi) 
  • Vacuum readout accuracy: ±2.0 in H2O, 0–18 in H2O
  • Ambient operating conditions:

                         -Temperature: 5–45° C (41–113° F)

                         -Humidity: 85% RH at 30° C non-condensing

                         -Height above sea level: 2000 m maximum (6,562 ft)

  • Approvals: CE, RoHS, WEEE, UL, and China RoHS compliant Meets or exceeds CE and CSA requirements